beautypg.com

Allied Telesis RAPIER I User Manual

Page 208

background image

10

Software Reference

Figure 1-6: Example script for a Single Ring, Two Domain Network - Node 1

# Node 1 (Master node for Ring_A - Transit Node for Ring_B)

# Set the Acceptable Frame Types parameter to admit only VLAN tagged frames.

# For Ring_A

set switch port=1 acc=vlan

set switch port=2 acc=vlan

# For Ring_B

set switch port=3 acc=vlan

set switch port=4 acc=vlan

#Create VLANs

# Ring_A

create vlan=control_ring_A vid=2

create vlan=data_ring_A vid=20

# Ring_B

create vlan=control_ring_B vid=3

create vlan=data_ring_B vid=30

# VLAN Port Configuration

# Ring_A

add vlan=control_ring_A port=1-2 frame=tagged

add vlan=data_ring_A port=1-2 frame=tagged

# Remove the Default VLAN from ports 1-2

del vlan=default po=1-2

# Ring_B

add vlan=control_ring_B port=3-4 frame=tagged

add vlan=data_ring_B port=3-4 frame=tagged

# Remove the Default VLAN from ports 3-4

del vlan=default po=3-4

EPSR Configuration

# create epsr domains

# domain_A

create epsr=domain_A mode=master controlvlan=control_ring_A primaryport=1

add epsr=domain_A datavlan=data_ring_A

enable epsr=domain_A

# domain_B

create epsr=domain_B mode=transit controlvlan=control_ring_B

add epsr=domain_B datavlan=data_ring_B

enable epsr=domain_B

This manual is related to the following products: