beautypg.com

Deactivating auxiliary functions – Burkert Type 8793 User Manual

Page 73

background image

73

Operation

19.1.1.1. Principle: Activating auxiliary functions with simultaneous

incorporation into the main menu

INPUT

X.TUNE

ADD.FUNCTION

INPUT

X.TUNE

ADD.FUNCTION

CHARACT

EXTRAS

CHARACT

EXTRAS

DIAGNOSE

Activating the auxiliary function

EXIT

ENTER

Setting.level

EXIT

ENTER

7

M A I N

ADD.FUNCTION

X.TUNE

INPUT

EXIT

ENTER

15

M A I N

X.CONTROL

ADD.FUNCTION

CARACT

X.TUNE

Functions in the main menu
(Standard)

Extended main menu

Figure 31:

Principle: Activating auxiliary functions with simultaneous incorporation into the main menu (MAIN)

19.1.2. Deactivating auxiliary functions

Procedure:

Key

Action

Description

MENU

Press

for approx. 3 s

Switching from process level

setting level.

/

Select

ADD.FUNCTION

ENTER

Press

The possible auxiliary functions are displayed.

/

Select the auxiliary function

ENTER

Press

Remove function mark (no cross ).

EXIT

Press

Acknowledgment and simultaneous return to the main menu (MAIN).
The marked function is now deactivated and removed from the
main menu.

Table 30:

Deactivating auxiliary functions

Deactivation removes the auxiliary function from the main menu (MAIN). This will cause the previous set-
tings, created under this function, to be rendered invalid.

English

Type 8792, 8793

This manual is related to the following products: