Description of System
11.6. Electrical data
Connections
2 cable glands (M20 x 1.5) with screw-type terminals 0.14 – 1.5 mm
2
or
circular plug-in connector
Operating voltage
24 V DC ± 10% max. residual ripple 10%
Power consumption
< 5 W
Input data for actual value signal
4 – 20 mA:
Input resistance
180 Ω
Resolution
12 bit
Frequency:
Measuring range
0 – 1000 Hz
Input resistance
17 kΩ
Resolution
1‰ of the measured value,
Input signal
> 300 mV
ss
Signal form
Sine, rectangle, triangle
Pt 100
Measuring range
-20 – +220 °C,
Resolution
< 0.1 °C,
Measurement current
< 1 mA
Input data for set-point value signal
0/4 – 20 mA:
Input resistance
180 Ω
Resolution
12 bit
0 – 5/10 V:
Input resistance
19 kΩ
Resolution
12 bit
Protection class
3 in accordance with VDE 0580
Analogue feedback
max. current
10 mA (for voltage output 0 – 5/10 V)
Burden (load)
0 – 560 Ω (for current output 0/4 – 20 mA)
Inductive proximity switches
100 mA current limit
Binary outputs
galvanically isolated
Current limiting
100 mA, output is clocked if overload occurs
Binary input
galvanically isolated
0 – 5 V = log “0”, 10 – 30 V = log “1”
inverted input in reverse order (input current < 6 mA)