Maintenance, Error messages and malfunctions, Error messages on the display – Burkert Type 8793 User Manual
Page 230: General error messages, Error.messages.and.malfunctions, . error.messages.on.the.display
230
Maintenance and Troubleshooting
34.
MAINTENANCE
The.Type.8792/8793.is.maintenance-free.when.operated.according.to.the.instructions.in.this.manual.
35.
ERROR MESSAGES AND MALFUNCTIONS
35.1. Error messages on the display
35.1.1. General error messages
Display
Causes.of.error
Remedial.action
min
Minimum input value has been reached Do not reduce value further
max
Maximum input value has been reached Do not increase value further
CMD error
Signal error
Set-point value positioner (position
controller)
Check signal
SP error
Signal error
Set-point value process controller
Check signal
PV error
Signal error
Actual value process controller
Check signal
PT100 error
Signal error
Actual value Pt-100
Check signal
invalid Code
Incorrect access code
Input correct access code
EEPROM fault
EEPROM defective
Not possible, device defective
Table 123:
General error message
english
Type 8792, 8793