beautypg.com

Burkert Type 8793 User Manual

Page 231

background image

231

Maintenance and Troubleshooting

35.1.2. Error and warning messages while the

X.TUNE function is

running

Display

Causes.of.error

Remedial.action

TUNE
err/break

Manual termination of self-parameterization
by pressing the

EXIT

key

X.TUNE locked

The

X.TUNE function is blocked

Input access code

X.TUNE
ERROR 1

No compressed air connected

Connect compressed air

X.TUNE
ERROR 2

Compressed air failed during Autotune
(

X.TUNE).

Check compressed air supply

X.TUNE
ERROR 3

Actuator or control system deaeration side
leaking

Not possible, device defective

X.TUNE
ERROR 4

Control system aeration side leaking

Not possible, device defective

X.TUNE
ERROR 5

The rotation range of the position sensor is
exceeded by 180°

Correct attachment of the position sensor
shaft on the actuator (see chapter “12.2”

and “12.3”).

X.TUNE
ERROR 6

The end positions for

POS-MIN and

POS-MAX are too close together

Check compressed air supply

X.TUNE
ERROR 7

Incorrect assignment

POS-MIN and

POS-MAX

To determine

POS-MIN and POS-MAX,

move the actuator in the direction indi-
cated on the display.

X.TUNE
WARNING 1**

Potentiometer is not coupled optimally to
the actuator.

An optimum connection can provide a more
accurate position measurement

Set middle position as described
in chapter “12.2.4. Aligning lever
mechanism”

.

** Warning information gives tips on optimized operation. The device is operational even if this warning information is not

observed. Warning information is automatically hidden after several seconds.

Table 124:

Error and warning message on X.TUNE

english

Type 8792, 8793