Auxiliary functions

26.2.2.

CUTOFF – Sealing function

This function causes the valve to be sealed outside the control area.

This is where you input the limits for the position set-point value (

CMD) as a percentage, from which the actuator

is fully deaerated or aerated.

Controlled operation opens or resumes at a hysteresis of 1 %.

If the process valve is in the sealing area, the message

„CUTOFF ACTIVE“ is indicated on the display.

Only.for.type.8793: Here you can select the set-point value to which the sealing function is to apply:

Type PCO

Process set-point value (

SP)

Type XCO

Position set-point value

(CMD)

If

Type PCO was selected, the limits for the process set-point value (SP) are input as a percentage with ref-

erence to the scaling range.

Factory setting:

Min = 0 %;

Max = 100 %;

CUT type = Type PCO

EXIT

*

OK

CUTOFF

Min 0 %

Max 100 %

CUT type

Type PCO

Type XCO

ENTER

INPUT

INPUT

INPUT

Available.for.Type.8793.only

SELEC

SELEC

Select process
set-point value

Select position
set-point value

EXIT

* If the submenu is left by pressing the

ESC

key, the value remains unchanged.

Figure 56:

Operating structure CUTOFF

The changed data is saved in the memory (EEPROM) only when there is a switch to the process level,
by leaving the main menu (MAIN) using the left selection key

EXIT

. During the save process, the save

symbol is indicated on the display.