Input signals from the control centre (e.g. plc) – Burkert Type 8793 User Manual
Page 57

57
Installation
Type 8792, 8793
english
15.1. Connection board of the Type 8792/8793 with
screw-type terminals
1
2
3
4
+24 V
GND
83 +
85 +
31 +
32 –
11 +
12 –
81 +
S +
S –
A
B
Optional:
Figure 27:
Designation of the screw-type terminals
Procedure:
→
Unscrew the 4 screws on the housing cover and remove the cover.
The screw-type terminals are now accessible.
→
Connect Type 8792/8793.
The procedure is described in the following chapters.
for Type 8792: chapter “15.2. Terminal assignment for cable gland - positioner Type 8792”
for Type 8793: chapter “15.3. Terminal assignment for cable gland - process controller Type 8793”
15.2. Terminal assignment for cable gland - positioner
Type 8792
15.2.1. Input signals from the control centre (e.g. PLC)
Terminal
Configuration
On.the.device.side
External.circuit./.Signal.level
11 +
Set-point value +
11 +
+ (0/4 – 20 mA or 0 – 5 / 10 V)
completely galvanically isolated
12 –
Set-point value GND
12 –
GND set-point value
81 +
Binary input +
81 +
+
0 – 5 V (log. 0)
10 – 30 V (log. 1)
specific to operating voltage GND
(terminal GND)
Table 16:
Terminal assignment; input signals of the control centre