Autofunction aoi, Table 124, Advanced register: autofunction aoi – ALLIED Vision Technologies Guppy F-503 User Manual
Page 273: See chapter, Table 124: advanced register: autofunction aoi
![background image](/manuals/326949/273/background.png)
Configuration of the camera
GUPPY Technical Manual V7.1.0
273
MinValue and MaxValue limits the range the auto gain feature is allowed to
use for the regulation process. Both values are initialized with the minimum
and maximum value defined in the standard GAIN_INQ register.
Changing the auto gain range might not affect the regulation, if the regu-
lation is in a stable condition and no other condition affecting the image
brightness is changed.
If both auto gain and auto shutter are enabled and if the gain is at its lower
boundary and shutter regulation is in progress, decreasing the lower auto
gain boundary has no effect on auto gain/shutter regulation as long as auto
shutter regulation is active.
Both values can only be changed within the range defined by the standard
GAIN_INQ register.
Autofunction AOI
The table below illustrates the advanced register for autofunction AOI.
The possible increment of the work area position and size is defined by the
YUNITS and XUNITS fields. The camera automatically adjusts your settings to
permitted values.
Register
Name
Field
Bit
Description
0xF1000390 AUTOFNC_AOI
Presence_Inq
[0]
Indicates presence of this
feature (read only)
---
[1..3]
Reserved
ShowWorkArea
[4]
Show work area
---
[5]
Reserved
ON_OFF
[6]
Enable/disable AOI (see note
above)
---
[7]
Reserved
YUNITS
[8..19]
Y units of work area/pos.
beginning with 0 (read only)
XUNITS
[20..31]
X units of work area/pos.
beginning with 0 (read only)
0xF1000394 AF_AREA_POSITION
Left
[0..15]
Work area position (left
coordinate)
Top
[16..31]
Work area position (top
coordinate)
0xF1000398 AF_AREA_SIZE
Width
[0..15]
Width of work area size
Height
[16..31]
Height of work area size
Table 124: Advanced register: Autofunction AOI