ALLIED Vision Technologies Guppy F-503 User Manual
Page 229
![background image](/manuals/326949/229/background.png)
Configuration of the camera
GUPPY Technical Manual V7.1.0
229
The entry with key D4 in the unit directory (440h in this case) provides the
offset for unit dependent info:
440h + 000001 * 4 = 444h
And finally, the entry with key 40 (448h in this case) provides the offset for
the camera control register:
FFFF F0000000h + 3C0000h * 4 = FFFF F0F00000h
The base address of the camera control register is thus:
FFFF F0F00000h
The offset entered in the table always refers to the base address of
F0F00000h.
Offset
0-7
8-15
16-23
24-31
434h
00
03
CRC
Unit directory
438h
12
00
A0
2D
43Ch
13
00
01
02
440h
D4
00
00
01
Table 96: Config ROM
Offset
0-7
8-15
16-23
24-31
444h
00
0B
CRC
Unit dependent info 448h
40
3C
00
00
44Ch
81
00
00
0A
450h
82
00
00
0E
454h
38
00
00
00
458h
39
00
00
00
45Ch
3A
00
00
00
460h
3B
00
00
00
464h
3C
00
00
00
468h
3D
00
00
00
46Ch
3E
00
00
00
470h
3F
00
00
00
Table 97: Config ROM