Trigger_mode_15 (bulk trigger) – ALLIED Vision Technologies Guppy F-503 User Manual
Page 175
![background image](/manuals/326949/175/background.png)
Controlling image capture
GUPPY Technical Manual V7.1.0
175
Trigger_Mode_15 (bulk trigger)
Trigger_Mode_15 is a bulk trigger, combining one external trigger event with
continuous or one-shot or multi-shot internal trigger.
It is an extension to the IIDC trigger modes. One external trigger event can
be used to trigger a multitude of internal image intakes.
This is especially useful for:
•
Grabbing exactly one image based on the first external trigger.
•
Filling the camera's internal image buffer with one external trigger with-
out overriding images.
•
Grabbing an unlimited number of images after one external trigger (sur-
veillance)
The next diagram shows this mode in detail.
Note
Trigger_Mode_15 is only available for Guppy CCD cameras.
Figure 101: Trigger_Mode_15
N x image; N: continuous, one_shot, multi_shot
External Trigger input, as applied at input pin