Description of the data path

GUPPY Technical Manual V7.1.0

116

In CMOS cameras offset and gain are in reversed order compared to the CCD
cameras. Therefore the offset is also amplified. So after changing gain, white
balance may also be changed.

From the user's point of view, the white balance settings are made in register
80Ch of IIDC V1.3. This register is described in more detail on the next page.

Figure 64: Signal path of MT9V022 (Guppy F-036 with CMOS sensor)

Figure 65: Signal path of MT9P031 (Guppy F-503 with CMOS sensor)

x

Pixel output

(reset minus signal)

Offset correction

Voltage (Reg0x48 or

result of BLC)

V

REF

(Reg0x2C)

Gain Selection

(Reg0x35 or

result of AGC)

ADC Data

(9:0)

C2

C1

10 (12) bit ADC

Pixel output

Analog

offset

ADC Data

(11:0)

12-bit ADC

Analog

gain

This manual is related to the following products: