Controlling image capture
GUPPY Technical Manual V7.1.0
173
Short exposure time:
If the following condition is true:
T
exp eff.
= T
exp
- T
frame
< 0
then you don’t get an IntEna signal and triggering is not possible.
Figure 99: Trigger_Mode_0: Guppy F-503 electronic rolling shutter (short exposure time)
IntEna
T
exp
T
frame
No overlapping,
no IntEna,
no flash
T
exp
– T
frame
< 0
FVal