Controlling image capture

GUPPY Technical Manual V7.1.0

173

Short exposure time:

If the following condition is true:

T

exp eff.

= T

exp

- T

frame

< 0

then you don’t get an IntEna signal and triggering is not possible.

Figure 99: Trigger_Mode_0: Guppy F-503 electronic rolling shutter (short exposure time)

IntEna

T

exp

T

frame

No overlapping,

no IntEna,

no flash

T

exp

– T

frame

< 0

FVal