beautypg.com

15 parallel programming characteristics, And t, Also apply to load- ing operation – Rainbow Electronics ATmega64M1 User Manual

Page 303

background image

303

8209A–AVR–08/09

ATmega16M1/32M1/64M1

1.

A: Load Command “0000 1000”.

2.

B: Load Address Low Byte, 0x00.

3.

Set OE to “0”, and BS1 to “1”. The Calibration byte can now be read at DATA.

4.

Set OE to “1”.

28.9.15

Parallel Programming Characteristics

Figure 28-7. Parallel Programming Timing, Including some General Timing Requirements

Figure 28-8. Parallel Programming Timing, Loading Sequence with Timing Requirements

(1)

Note:

1. The timing requirements shown in

Figure 28-7

(i.e., t

DVXH

, t

XHXL

, and t

XLDX

) also apply to load-

ing operation.

Data & Contol

(DATA, XA0/1, BS1, BS2)

XTAL1

t

XHXL

t

WLWH

t

DVXH

t

XLDX

t

PLWL

t

WLRH

WR

RDY/BSY

PAGEL

t

PHPL

t

PLBX

t

BVPH

t

XLWL

t

WLBX

t

BVWL

WLRL

XTAL1

PAGEL

t

PLXH

XLXH

t

t

XLPH

ADDR0 (Low Byte)

DATA (Low Byte)

DATA (High Byte)

ADDR1 (Low Byte)

DATA

BS1

XA0

XA1

LOAD ADDRESS

(LOW BYTE)

LOAD DATA

(LOW BYTE)

LOAD DATA

(HIGH BYTE)

LOAD DATA

LOAD ADDRESS

(LOW BYTE)