Printronix SL5000r RFID Smart Label and Thermal Printers User Manual
Page 342
342
Chapter
6
Restore The Printer To Operation
TESTING
HARDWARE
PLEASE WAIT
Yes
Normal power-up
message. Printer is
running its initialization
routine.
1.
No action required.
2.
If the printer does not
complete initialization and
continues displaying this
message when the CT
emulation is installed, the
expansion CT board may
not be connected to the
controller PCBA.
Unscannable:
xx Missing Codes
Yes
Data validation error:
missing barcode.
Check the paper and ribbon for
cleanliness, wrinkles, etc., or
an obstructed validator beam.
If there is no validator beam at
all, or if the LED is not flashing
as barcodes pass through the
validator beam, recycle
validator power. If the problem
persists, contact your service
representative.
NOTE: xx represents the
number of missing
barcodes (on the form)
that caused the
warning/fault to be
declared.
Validator not
communicating
Yes
The Validator Funct. =
Enable in the
VALIDATOR menu, but
when the printer was
first powered up it
could not communicate
with the validator.
Check that the validator signal
cable is securely connected to
the validator unit.
WAITING FOR
PROGRAM
DOWNLOAD
Yes
Normal message when
the printer is powered
up while holding down
both the MENU key
and the DOWN arrow
key in preparation to
download software to
the printer.
1.
Complete the downloading
software procedure. See
“Downloading Software”
on page 279.
2.
Exit this procedure by
cycling printer power.
Table 17. LCD Message Troubleshooting (continued)
Displayed Message
Can User
Correct?
Explanation
Solution