211

FF valid at TOF

The FF valid at TOF option determines whether the printer will perform a
Form Feed when the host sends a Form Feed command, if the printer is at the
top of form.

Enable. Performs a form feed when the host sends a Form Feed
command and the printer is at the top of form.

Disable. Will not perform a form feed when the host sends a Form Feed
command and the printer is at the top of form.

The factory default is Enable.

FF Validity

Determines if the position of a Form Feed (FF) command affects its execution.

Off. Performs a form feed only if it occurs at the first print position in a line
or at Maximum Print Position +1. An FF command at any other position is
recognized as a blank.

On. Allows the printer to perform an FF command anywhere in the data
stream.

The factory default is Off.

Form Length (in.)

Form length is the number of lines that can be printed on a label. You can set
forms length in inches.

The factory default is shown in Table 3 on page 122.

Form Length (lines)

Form length is the number of lines that can be printed on a label. You can set
forms length as a function of the current LPI (lines per inch).

The factory default is shown in Table 3 on page 122.

Form Length (mm)

Form length is the number of lines that can be printed on a label. You can set
forms length in millimeters.

The factory default is shown in Table 3 on page 122.

Form Width (char.)

The forms width can be specified as a function of the current CPI (characters
per inch). The forms width set should not exceed the actual paper width.

The factory default is the maximum printing width divided by the selected
number of characters per inch.