beautypg.com

Printronix SL5000r RFID Smart Label and Thermal Printers User Manual

Page 229

background image

Emulation Submenus

229

Skip Cmd Prefix

Stands for Skip Command Prefix. This parameter determines if the printer will
print any data before a PGL command is received.

Enable (the default). The printer ignores all data before a PGL command.

Disable. The printer will print all data before a PGL command.

Slash 0

This parameter allows you to print the numeral “0” with or without the slash.
This option applies to all character sets except OCR A and OCR B.

Disable (the default). Zero is printed without a slash.

Enable. Zero is printed with a slash.

Slashed Zero

This parameter allows you to print the numeral “0” with or without the slash.
This option applies to all character sets except OCR-A and OCR-B.

Disable (the default). Zero is printed without a slash.

Enable. Zero is printed with a slash.

Slew Relative

“Slewing” is rapid vertical paper movement. This parameter determines the
number of lines slewed (either 1-15 lines or 1-16 lines) when an EVFU Slew
Relative command is received.

The options are 1-15 lines (the default) and 1-16 lines.

SPC Char Set

Allows you to select the print language character set. See page 170 for the
options.

The default is 0500 Internat 5.

SPC Null Supp

SPC Null Supp stands for SPC Null Suppression.

Disable (the default). Ignores nulls. The print position does not move.

Enable. Treats nulls as blank spaces.

SPC Space Supp

This option is only available in Coax SPC emulation and is used in LU3/DSC/
DSE mode only.

Disable (the default). Treats nulls and spaces normally.

Enable. If the entire line consists of spaces and nulls, the line will be
discarded.