Do FF at TOF

Determines whether the printer, with media already set at the TOF (Top-of-
Form) position, will advance media to the next TOF position upon receipt of
an FF command.

Enable. The printer will advance media from the present TOF position to
the next TOF position upon receipt of an FF command, causing a blank
form.

Disable. The printer will not advance media from the present TOF
position to the next TOF position upon receipt of an FF command.

The factory default is Enable.

Early Print Cmpl (Coax, TN3270)

Early Print Complete capability allows the printer to send print (order)
complete status to the host before the printer is actually done printing all data.
This option is valid only when the printer is in DSC/DSE mode.

Disable. The printer will suppress the Early Print Complete response until
all printing is complete.

Enable. The printer will send an acknowledgement to the host when it is
able to accept more data.

NOTE: When an Early Print Complete is enabled and an error occurs, there

may be data loss.

The factory default is Disable.

Early Print Comp (IPDS)

This parameter allows you to choose when to send a Print Complete to the
Controller.

Off. Print Complete is sent if the page is printed completely.

On. Print Complete is sent immediately. The next page will be created.
This improves the print performance when starting the next page, but
degrades error recovery.

The factory default is Off.

Elong./Alt. Font

Controls which host command sets elongated (double high) fonts and
extended character set.

ELNG=BS (hex 08) FONT=SO (hex 0E)

ELNG=SO FONT=BS

The factory default is Elng=BS Font=SO.