Calibrate ctrl, Table 6 o, N in table 6 – Printronix SL5000r RFID Smart Label and Thermal Printers User Manual
Page 138: Chapter 3
138
Chapter
3
CALIBRATE CTRL
CALIBRATE CTRL
CALIBRATE
CTRL
(from page 96)
Gap/Mark
Sensor
1
Auto
Calibrate
Media
Profile
Disable*
Mark
Gap
Advanced Gap
Advanced Notch
Sensed
Distance
0.00 inches
2
Pwr Up
Action
Disable*
Auto-Cal
Seek TOF
Gap/Mark
Thresh
171*
000 to 255
Gap Length
0.12 inches*
0.05 to 1.00 inches
Min Calib
Delta
012*
3
012 to 050
Use Label
Length
Enable*
Disable
Paper Out
Thresh
180*
000 to 255
Manual
Calibrate
Online
Auto-Cal
Disable*
Enable
Gap
Windowing
Disable*
Enable
Cal in Peel
Mode
Disable*
Enable
Threshold
Range
50%*
5% to 95%
Dynamic
Sensing
Disable
Enable*
Run Calibrate
Print Profile
Paper Out
Sensor
1
Reflective*
Transmissive
Run Calibrate
Notes:
* = Factory Default
Italicized
items are available only when you enable Admin User (in the PRINTER CONTROL menu).
1
Gap/Mark Sensor and Paper Out Sensor work in conjunction, as shown below:
If you change the Gap/Mark Sensor or Paper Out Sensor, you must recalibrate the media.
2
When Admin User is enabled (in the PRINTER CONTROL menu), you can change the unit value to millimeters:
Under the Units submenu (in the MEDIA CONTROL menu), enable the “In Millimeters” option.
3
When Gap/Mark Sensor = Disable, Gap, or Mark, the default is 12. When Gap/Mark Sensor = Advanced Gap or
Advanced Notch, the default is 20.
Table 6
When you select an
option in Gap/Mark
Sensor...
Paper Out Sensor
defaults to...
Disable
Reflective
Mark
Reflective
Gap
Reflective
Advanced Gap
Transmissive
Advanced Notch
Transmissive
HeadClose
Action
Disable*
Auto-Cal
Seek TOF