E6581381

E-30

5

3)

Using other speed commands with preset-speed command

Command mode

selection

EOQF

0: Terminal board

1: Operation panel

2: Serial communication

Frequency setting

mode selection
HOQF

1: VIA
2: VIB
5: UP/DOWN

3: Operation

panel

4:Commun

ication

1: VIA
2: VIB
5: UP/DOWN

3: Operation

panel

4:Commun

ication

1: VIA
2: VIB
5: UP/DOWN

3: Operation

panel

4:Commun

ication

Entered

Preset-speed command valid Note)

Terminal

command

valid

Operation

panel

command

valid

Terminal

command

valid

Operation

panel

command

valid

Communicatio

n command

valid

Communic

ation

command

valid

Preset-

speed

command

Not

entered

Terminal

command

valid

Operation

panel

command

valid

Communic

ation

command

valid

Note: The preset-speed command is always given priority when other speed commands are input at the

same time.

Below is an example of 7-step speed operation.

ON
OFF

F-CC

R-CC

RES-CC

VIA-CC

ON
OFF

ON
OFF

ON
OFF

UT

UT

UT

UT

UT

UT

UT

Output frequency
[Hz]

Time
[sec]

0

Example of 7-step speed operation

(The inverter doesn't accept Preset-
speed command.)

(The inverter doesn't accept Preset-
speed command.)