Toshiba VF-FS1 User Manual
Toshiba, Industrial inverter, Instruction manual

Instruction Manual
Industrial Inverter
TO
S
V
E
R
T VF
-FS
1
II
II
1
2
3
4
5
6
7
8
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
E6581381
R
ead
first
I
S
afety
precautions
I
ntroduction
C
ontents
C
onnection
O
perations
B
asic
VF -FS1
operations
B
asic
parameters
E
xtended
parameters
A
pplied
operation
M
onitoring
the
operation
status
M
easures
to
satisfy
the
standards
P
eripheral
devices
T
able
of
parameters
and
data
S
pecifications
B
efore
making
a
service
call
I
nspection
and
maintenance
W
arranty
D
isposal
of
the
inverter
NOTICE
1. Make sure that this instruction manual is delivered to the
end user of the inverter unit.
2. Read this manual before installing or operating the inverter
unit, and store it in a safe place for reference.
Instruction Manual
TOSVERT
TM
VF-
FS1
3-phase 200V class 0.4
VQ30kW
3-phase 400V class 0.4
VQ30kW
2006 Ver. 100/101
TOSHIBA
INDUSTRIAL AND POWE R
SYSTEMS & SE RVICES COMPANY
OVERSEAS SALES & MARKETING DEPT.
ELECTRICAL APPARATUS & MEASUREMENT
DIV.
1-1, Shibaura 1-chome, Minato-Ku,
Tokyo 105-8001, Japan
TEL: +81-(0)3-3457-4911
FAX: +81-(0)3-5444-9268
TOSHIBA I NTERNATIONAL
CORPORATION
13131 West Little York RD., Houston,
TX 77041, U.S.A
TEL: +1-713-466-0277
FAX: +1-713-896-5226
TOSHIBA ASIA P ACIFIC PTE., LT D
152 Beach Rd., #16-00 Gateway East,
Singapore 189721
TEL: +65-6297-0900
FAX: +65-6297-5510
TOSHIBA CHINA CO., LT D
23rd Floor, HSBC Tower, 101 Yin Cheng
East Road, Pudong New Area, Shanghai
200120, The People's Republic of China
TEL: +86-(0)21-6841-5666
TOSHIBA I NTERNATIONAL CORPORATION PTY.,
LTD
2 Morton Street Parramatta, NSW2150, Australia
TEL: +61-(0)2-9768-6600
FAX: +61-(0)2-9890-7542
TOSHIBA I NFORMATION, I NDUSTRIAL AND
POWER SYSTE MS T AIWAN CORP.
6F, No66, Sec1 Shin Sheng N.RD, Taipei, Taiwan
TEL: +886-(0)2-2581-3639
FAX: +886-(0)2-2581-3631
For further information, please contact your nearest Toshiba Liaison Representative or International Operations - Producer Goods.
The data given in this manual are subject to change without notice.
2006-01
Industrial Inverter
For 3-phase induction motors
Document Outline
- Cover
- I. Safety precautions
- II. Introduction
- Contents
- 1. Read first
- 2. Connection
- 3. Operations
- 4. Basic VF-FS1 operations
- 5. Basic parameters
- 5.1 Setting acceleration/deceleration time
- 5.2 Specifying an operation mode, using parameters
- 5.3 Selection of operation mode
- 5.4 Meter setting and adjustment
- 5.5 Standard default setting
- 5.6 Forward/reverse run selection (Operation panel operation)
- 5.7 Maximum frequency
- 5.8 Upper limit and lower limit frequencies
- 5.9 Base frequency
- 5.10 Selecting control mode
- 5.11 Manual torque boost - increasing torque boost at low speeds
- 5.12 Setting the electronic thermal
- 5.13 Preset-speed operation (speeds in 7 steps)
- 6. Extended parameters
- 6.1 Input/output parameters
- 6.2 Input signal selection
- 6.3 Terminal function selection
- 6.4 Basic parameters 2
- 6.5 Frequency priority selection
- 6.6 Operation frequency
- 6.7 DC braking
- 6.8 Auto-stop in case of lower-limit frequency continuous operation
- 6.9 Jump frequency - jumping resonant frequencies
- 6.10 Bumpless operation
- 6.11 PWM carrier frequency
- 6.12 Trip-less intensification
- 6.13 Droop control
- 6.14 Conducting PID control
- 6.15 Setting motor constants
- 6.16 Acceleration/deceleration time 2
- 6.17 Protection functions
- 6.18 Forced fire-speed control function
- 6.19 Adjustment parameters
- 6.20 Operation panel parameter
- 6.21 Communication function (Common serial)
- 6.22 Parameters for options
- 6.23 Permanent magnetic motors
- 7. Applied operation
- 8. Monitoring the operation status
- 9. Measures to satisfy the standards
- 10. Peripheral devices
- 11.Table of parameters and data
- 12. Specifications
- 13. Before making a service call - Trip information and remedies
- 14. Inspection and maintenance
- 15. Warranty
- 16. Disposal of the inverter