1 how to start and stop – Toshiba VF-FS1 User Manual
Page 49

E6581381
C-3
3
3.1.1 How to start and stop
■
Example of a EOQF setting procedure
Key operated
LED display
Operation
Displays the operation frequency (operation stopped).
(When standard monitor display selection H= [Operation
frequency])
CWH
Displays the first basic parameter [Wizard function (CWH)].
EOQF
Press either the or key to select “EOQF”.
Press ENT key to display the parameter setting. (Default setting:).
Change the parameter to (panel) by pressing the key.
⇔EOQF
Press the ENT key to save the changed parameter. EOQF and the
parameter set value are displayed alternately.
(1) Start and stop using the operation panel keys (EOQF=)
Use the and keys on the operation panel to start and stop the motor.
: Motor starts.
: Motor stops.
+
To switch between forward run and reverse run from the control panel, the parameter HT
(forward/reverse run selection) needs to be set to or .
(2) RUN/STOP by means of an external signal to the terminal board (EOQF=):
Sink (Negative) logic
Use external signals to the inverter terminal board to start and stop the motor.
Short and terminals: run forward
Frequency
ON
OFF
F-CC
Slow down
and stop
F
Open and terminals: slow down and stop
CC
F
CC
(3) Coast stop
The standard default setting is for slowdown stop. To
make a coast stop, assign a "1(ST)" terminal function
to an idle terminal using the programmable terminal
function.
Change to H=.
For coast stop, open the ST-CC when stopping the
motor in the state described at left.The monitor on the
inverter at this time will display QHH.
Motor
speed
ON
OFF
ON
OFF
F-CC
ST-CC
Coast stop
MODE
ENT
ENT
STOP
RUN
RUN
STOP