beautypg.com

10 selecting control mode – Toshiba VF-FS1 User Manual

Page 84

background image

E6581381

E-18

5

5.10 Selecting control mode

RV

: V/F control mode selection

• Function

With VF-FS1, the V/F controls shown below can be selected.

{

V/F constant

{

Variable torque

{

Automatic torque boost control

{

Vector control

{

Energy saving

{

PM motor control

[Parameter setting]

Title

Function

Adjustment range

Default setting

RV

V/F control mode selection

0: V/F constant
1: Variable torque
2: Automatic torque boost control
3: Vector control
4: Energy-saving
5: - (Do not select)
6: PM motor control

1

Steps in setting are as follows
(In this example, the V/F control mode selection parameter RV is set to (Vector control).

Setting V/F control mode selection to 3 (sensorless vector control)

Key operated

LED display

Operation

.

Displays the operation frequency. (Perform during operation stopped.)
(When standard monitor display selection H is set to
[Operation frequency])

CWH

The first basic parameter “CWH” (Wizard function) is displayed.

RV

Press the key to change the parameter to RV (V/F control mode
selection).

Press the ENT key to display the parameter setting. (Standard
default setting: ( Variable torque)).

Press the key to change the parameter to (vector control).

⇔ RV

Press the ENT key to save the changed parameter. RV and
parameter set value “” are displayed alternately.

MODE

ENT

ENT