E6581381

E-13

5

5.5

Standard default setting

V[R

: Default setting

Function
Allows setting of all parameters to the standard default setting, etc. at one time.
Note that HO, HOUN, H, H

∼ H and H will not be reset to their factory

default settings.

Title

Function

Adjustment range

Default setting

V[R

Default setting

0: -
1: 50Hz default setting
2: 60Hz default setting
3: Standard default setting

(Initialization)

4: Trip record clear
5: Cumulative operation time clear
6: Initialization of type information
7: Save user-defined parameters
8: Call user-defined parameters
9: Cumulative fan operation time

record clear

0

+

This function will be displayed as 0 during reading on the right. This previous setting is displayed.
Example:

+ V[R

cannot be set during the inverter operating. Always stop the inverter first and then program.

Programmed value

50Hz default setting (V[R = )

Setting V[R at causes all the following parameters to be set for operation using a base frequency of 50
Hz. (This does not change the setting of any other parameters.)
Parameter HJ, WN, XN, H, H, H, H: 50Hz
Parameter H: According to model
⇒ See page K-14.

50Hz default setting (V[R = )

Setting V[R at causes all the following parameters to be set for operation using a base frequency of 60
Hz. (This does not change the setting of any other parameters.)
Parameter HJ, WN, XN, H, H, H, H: 60Hz
Parameter H: According to model
⇒ See page K-14.