5. Basic parameters

Before you operate the inverter, the parameters that you must first program are the basic parameters.

5.1

Setting acceleration/deceleration time

CW

:Automatic acceleration/deceleration

CEE

:Acceleration time 1

FGE

:Deceleration time 1

• Function

1) For acceleration time 1 CEE programs the time that it takes for the inverter output frequency to go from

0Hz to maximum frequency HJ.

2) For deceleration time 1 FGE programs the time that it takes for the inverter output frequency to got

from maximum frequency HJ to 0Hz.

5.1.1 Automatic acceleration/deceleration

This automatically adjusts acceleration and deceleration time in line with load size.

CW

=

* Adjusts the acceleration/deceleration time automatically within the range of 1/8 to 8 times as long as the

time set with the CEE or FGE, depending on the current rating of the inverter.

CW

=

* Automatically adjusts speed during acceleration only. During deceleration, speed is not adjusted

automatically but reduced at the rate set with FGE.

Output
frequency (Hz)

Deceleration

time

Acceleration

time

HJ

When load is small

Time
[sec]

0

Shorten acceleration/deceleration time

Deceleration

time

Acceleration

time

HJ

When load is large

Output
frequency (Hz)

Time
[sec]

0

Lengthen acceleration/deceleration time

Set CW (automatic acceleration/deceleration) to or .