[Parameter setting]

Title

Function

Adjustment range

Default setting

CEE

Acceleration time 1

0.0-3200 sec.

According to model
(

⇒ See page K-14)

FGE

Deceleration time 1

0.0-3200 sec.

According to model
(

⇒ See page K-14)

Note:When the acceleration/deceleration time is set at 0.0 seconds, the inverter speed increases or reduces

speed within 0.05 seconds.

+

If the programmed value is shorter than the optimum acceleration/deceleration time determined by load
conditions, overcurrent stall or overvoltage stall function may make the acceleration/deceleration time
longer than the programmed time. If an even shorter acceleration/deceleration time is programmed, there
may be an overcurrent trip or overvoltage trip for inverter protection.
⇒ For further details, see section 13.1.