F-76

6

6.20.6 Selection of operation panel stop pattern

H

: Selection of operation panel stop pattern

• Function

This parameter are used to select a mode in which the motor started by pressing the key on the
operation panel is stopped when the key is pressed.

1)

Slowdown stop
The motor slows down to a stop in the deceleration time set with FGE (or H).

2)

Coast stop
The inverter cuts off power supply to the motor. The motor comes to a stop after coasting for a while by
inertia. Depending on the load, the motor may keep running for a good long time.

[Parameter setting]

Title

Function

Adjustment range

Default setting

H

Selection of operation panel stop
pattern

0: Slowdown stop
1: Coast stop

0

6.20.7 Display of the head of the parameters

H

: Head of the parameter display selection

• Function

The parameter can be set at the front of the setting monitor mode.
If selecting “1:CWJ”, the Wizard parameter “CWH” is not displayed.

[Parameter setting]

Title

Function

Adjustment range

Default setting

H

Head of parameter display
selection

0: AUF
1: AUH

0

6.20.8 Integral output power

H

: Integral output power retention selection

H

: Integral output power display unit selection

• Function

At the main power off ,it is selectable whether retention of integral output power values or not.
And also, the display unit is selectable.

STOP

RUN