beautypg.com

Specifications, 1 models and their standard specifications, Standard specifications – Toshiba VF-FS1 User Manual

Page 229

background image

E6581381

L-1

12

12. Specifications

12.1 Models and their standard specifications

Standard specifications

Item

Specification

Input voltage

3-phase 200V

Applicable motor (kW)

0.4

0.75

1.5

2.2

4.0

5.5

7.5

11

15

18.5

22

30

Type

VFFS1

Form

2004PM 2007PM 2015PM 2022PM 2037PM 2055PM 2075PM 2110PM 2150PM 2185PM 2220PM 2300PM

Capacity (kVA) Note 1)

1.1

1.8

2.9

4.0

6.7

9.2

12.2

17.6

23.2

28.5

33.5

44.6

Rated output/current

(A) Note 2)

2.8

4.6

7.5

10.6

17.5

24.2

32

46.2

61

74.8

(67.3)

88.0

(79.2)

117.0

(105.3)

Output voltage Note 3)

3-phase 200V to 240V

Rat

ing

Overload current rating

110%-60 seconds, 180%-2 second

Voltage-current

3-phase 200V to 240V - 50/60Hz

Po

w

er

suppl

y

Allowable fluctuation

Voltage + 10%, -15% Note 4), frequency ±5%

Protective method

IP20 Enclosed type (JEM1030)

IP00 Enclosed

type

(JEM1030)

Note 5)

Cooling method

Forced air-cooled

Color

Munsel 5Y-8/0.5

Built-in filter

Basic filter

Item

Specification

Input voltage

3-phase 400V

Applicable motor (kW)

0.4

0.75

1.5

2.2

4.0

5.5

7.5

11

15

18.5

22

30

Type

VFFS1

Form

4004PL 4007PL 4015PL 4022PL 4037PL 4055PL 4075PL 4110PL 4150PL 4185PL 4220PL 4300PL

Capacity (kVA) Note 1)

1.1

1.6

2.8

3.9

6.9

9.1

12.2

17.1

23.2

28.2

33.2

44.6

Rated output current

(A) Note 2)

1.4

2.2

3.7

5.1

9.1

12.0

16.0

22.5

30.5

37.0

(33.3)

43.5

(39.2)

58.5

(52.7)

Rated output voltage

Note 3)

3-phase 380V to 480V

Rat

ing

Overload current rating

110%-60 seconds, 180% -2 second

Voltage-current

3-phase 380V to 480V - 50/60Hz

Po

w

er

suppl

y

Allowable fluctuation

Voltage + 10%, -15% Note 4), frequency ±5%

Protective method,

IP20 Enclosed type (JEM1030)

IP00 Enclosed

type (JEM1030)

Note 5)

Cooling method

Forced air-cooled

Color

Munsel 5Y-8/0.5

Built-in filter

EMI filter

Note 1: Capacity is calculated at 220V for the 200V models, at 440V for the 400V models.
Note 2: The rated output current in the parenthesis is at 12kHz of PWM carrier frequency (H) setting.
Note 3: Maximum output voltage is the same as the input voltage.
Note 4: ±10% when the inverter is used continuously (load of 100%).
Note 5: Inverter, 22kW or greater, do not have wiring port covers, they have large openings, but there is no space to bend the

external cables inside the unit. If they are fitted external to the cabinet, please use an optional wiring port cover.