Toshiba VF-FS1 User Manual
Page 211

E6581381
K-3
11
Title
Communication
No.
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
RV
0015
V/F control mode
selection
-
-
0: V/F constant
1: Variable torque
2: Automatic torque boost control
3: Vector control
4: Energy-saving
5: - (Do not select)
6: PM motor control
2
5.10
XD
0016
Torque boost 1
%
0.1/0.1
0.0-30.0
* 2
5.11
VJT
0600
Motor electronic-
thermal protection
level 1
%
(A)
1/1
10-100
100
5.12
6.17.1
Setting
Overload protection OL stall
0
{
Ч
1
{
{
2
Ч
Ч
3
Standard
motor
Ч
{
4
{
Ч
5
{
{
6
Ч
Ч
QNO
0017
Electronic-thermal
protection
characteristic
selection *3
-
-
7
VF motor
×
{
0
5.12
UT
0018
Preset-speed
operation
frequency 1
Hz
0.1/0.01
NN
-WN
15.0
UT
0019
Preset-speed
operation
frequency 2
Hz
0.1/0.01
NN
-WN
20.0
UT
0020
Preset-speed
operation
frequency 3
Hz
0.1/0.01
NN
-WN
25.0
UT
0021
Preset-speed
operation
frequency 4
Hz
0.1/0.01
NN
-WN
30.0
UT
0022
Preset-speed
operation
frequency 5
Hz
0.1/0.01
NN
-WN
35.0
UT
0023
Preset-speed
operation
frequency 6
Hz
0.1/0.01
NN
-WN
40.0
UT
0024
Preset-speed
operation
frequency 7
Hz
0.1/0.01
NN
-WN
45.0
5.13
H
-
Extended
parameters
-
-
-
-
-
4.2.2
ITW
-
Automatic edit
function
-
-
-
-
-
4.2.3
*1 : 230 (WP/WN type), 400 (WP type), 460 (WN type)
*2 : Default values vary depending on the capacity.
⇒ See the table of page K-14.
*3 : { : valid,
× : invalid