1 opening the io window – Renesas REJ10J1837-0100 User Manual
Page 350
![background image](/manuals/200062/350/background.png)
High-performance Embedded Workshop
17. Using the Debugger
REJ10J1837-0100 Rev.1.00 Nov. 16, 2008
335
17.6.1
Opening the IO window
To open the IO window, choose [View -> CPU -> IO] or click the View IO toolbar button (
). Modules that match
the on-chip peripheral modules organize the I/O register information.
The IO window has two tabs: All Register and Selected Register.
When the IO window is first opened, only a list of module names is shown on the All Register tabbed pane.
Window configuration
Tab
Description
All Register
Shows all I/O registers.
Selected Register
Shows selected I/O registers. This page is blank by default.
• I/O registers can be expended.
• If the value of an I/O register is changed, the value is displayed in red.
• Double-clicking on the line of an I/O register opens a dialog box, in which you can change the value.
Changing of the value can be recorded in a macro (Macro Recording).
• The values of I/O registers and their bits can be changed in the Value column by in-place editing (Macro
Recording).
Options
Right-clicking displays a pop-up menu containing available options.
A basic operation is allocated to the toolbar.
The Toolbar display and Customize toolbar options are also included in the pop-up menu opened by right-clicking on
the toolbar.
Pop-up Menu Option
Toolbar Button
Macro Recording
Function
Refresh
-
Refreshes the IO window.
Lock Refresh
-
Disables refresh of the IO window.
Load IO File
-
Manually loads an I/O file.
Selected IO Register
-
Selects the I/O register(s) to be shown on the Select Register
tabbed pane.
-
Prints the current data of the window.
Save To File
-
Saves the current data of the window to a text file.