background image

High-performance Embedded Workshop

16. Using the Test Support Facility

REJ10J1837-0100 Rev.1.00 Nov. 16, 2008
246

Failed at symbol

Name of the unmatched symbol

Src

Content of the test-image file

Dest

Data in the current High-performance Embedded Workshop system or in another
test-image file to be compared with

Test result details

Example

Failed at symbol i, Src = (int)H'00000001{R14}, Dest = (int)H'00000000{R14}

To make detailed setting

If you double-click on a test item in the Create New Test Image dialog box, a further dialog box for detailed setting
opens.

1. To specify a symbol to be saved into the test-image file, select the checkbox for that symbol. The selected

symbol is shown in Current Setting.

2. Click OK.

16.6.2.3 Symbol-ASMWatch (ASMWatch window)

The following table shows information on the test-image data to be saved into test-image files and test results (not
matched).

Test group name

Symbol

Test item name

ASMWatch

Test-image data to be

Values set as detailed information and the range of data in the ASMWatch window acquired with this