background image

Uniform Dialing Plan

389

— DN 3101 can call DN 3002 by dialing "3002", instead of the

"65013002" dialed in Normal Mode.

— DN 3002 can call DN 3001 by dialing "65013001", instead of the

"3001" dialed in Normal Mode.

— DN 3002 can call DN 3101 by dialing "3101", instead of the

"65043101" dialed in Normal Mode.

Configuration example

Main office

To configure UDP at the main office, do the following:

Step

Action

1

Configure ESN Control Block for UDP.

>LD 86

REQ NEW

CUST 0

FEAT ESN

AC1 6

2

Configure Digit Manipulation (DGT).

>LD 86

REQ NEW

FEAT DGT

DMI 6

DEL 3

3

Configure UDP LOC.

>LD 90

REQ NEW

FEAT NET

TRAN AC1

TYPE LOC

LOC 504

FLEN 7

RLI 12

LDN 0

4

Configure UDP HLOC.

>LD 90

REQ NEW

FEAT NET

TRAN AC1

TYPE HLOC

HLOC 501

DMI 6

Nortel Communication Server 1000

Branch Office Installation and Commissioning

NN43001-314

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2007, Nortel Networks

.