Nortel Networks NN43001-314 User Manual
Page 277
Installing and configuring IP Phones
277
A Branch User Identification (BUID) and Main Office TN (MOTN) can be
provisioned, if the Internet telephone belongs to a MG 1000B Branch Office.
The local TN configured for the Branch Office set with CS 1000 Release 5.0
accepts a four-field format.
This prompt accepts TN’s in two or four-field format. If nothing is entered
for the BUID, then the set does not get automatically redirected to the
Main Office. The value of BUID and MOTN are assigned in the TN block
when the crafts person performs the Branch User Config. At this time the
User ID entered is saved as the value of BUID and the Main Office TN is
saved as the MOTN. Once the value for BUID and MOTN are known at the
Branch Office, a set is automatically redirected to the Main Office when
the set re-powers or when WAN connectivity to the Main Office is restored
after being temporarily lost.
Table 24
LD 11 Branch Office changes for Internet Telephones
Prompt
Responses
Description
Pkg#
REQ
NEW/CHG
TYPE
2004P1, 200
4P2/2050PC,
2050MC/2002
P1,2002P2/20
01P2, 1110,11
20,1140, 1150,
2007,2033
Internet telephones.
CUST
Customer number.
TN
c u , l s c u
With CS 1000 Release 5.0 MG 1000B
with MGC, the TN entered for an IP
Phone is 4-field format.
Prompt
Responses
Description
Pkg#
BUID
dialable DN, Main
Office user id Enter X
to delete
390
MOTN
I s c u or c u
Main Office TN The
default is the Branch
Office TN entered
above, which for CS
1000 Release 5.0 MG
1000B with MGC, will
be 4-field format.
390
Nortel Communication Server 1000
Branch Office Installation and Commissioning
NN43001-314
01.02
Standard
Release 5.0
20 June 2007
Copyright © 2007, Nortel Networks
.