Converting a Small System to a Branch Office
2
For each Small System that is to be converted to a Branch Office:
a. Power down the system, including reserve power if so equipped.
b. Upgrade the system controller card if required. Refer to Meridian
1 Small System Software -only Upgrade (NN43011-459).
c. Install a Voice Gateway Media Card if required. Refer to IP Line
Fundamentals (NN43100-500).
If the Small System already has a Voice Gateway Media Card,
upgrade it to IP Line 4.5. Refer to IP Line Fundamentals
(NN43100-500).
d. Install a Signaling Server if required. Follow the procedures in
"Installing a Signaling Server" (page 228)
A Signaling Server must be installed on an Meridian Option
11C/Meridian 1 PBX 11C Cabinet, or Meridian Option 11C
Mini/Meridian 1 PBX 11C Chassis system. A CS 1000M Small
System already has a Signaling Server installed.
e. Configure the Signaling Server.
1. Run the Signaling Server Install Tool, as described in
Installing the Signaling Server software
.
2. Transfer the node information using Element Manager. Refer
to IP Line Fundamentals (NN43100-500).
f.
Install the Branch Office software, using the Branch Office
keycodes. Follow
Installing and provisioning an MG 1000B
. At
the specified menus, select the following:
1. At the Branch Office Software Installation Main Menu (
step
1
), select the following option:
3.
New System Installation — From Software
Delivery Card
2. At the Select Database menu (
step 8
), select the following
option to use the existing database:
3.
Archived database
The software for a Branch Office is significantly different from the
software for a Small System.
g. Configure the Branch Office (Customer Data Block and ELAN
subnet). See
Procedure 23 "Configuring the MG 1000B zone"
.
h. Configure the Branch Office dialing plan. See
.
Nortel Communication Server 1000
Branch Office Installation and Commissioning
NN43001-314
01.02
Standard
Release 5.0
20 June 2007