Using This

Control:

Does This:

Control Unit

Local/Remote

Switch

Establishes where control unit power is controlled.

On Printer 1

- When this switch is in the Local position, the PUM is

powered on and off by the Control Unit Power On and the Control

Unit Power Off if in Local

switches. In the Remote position, the PUM

is powered on and off by Printer 2 control unit power controls.

On simplex printers and Printer 2 of a duplex configuration

- When

this switch is in the Local position, the AFCCU is powered on and off

by the Control Unit Power On and the Control Unit Power Off if in

Local

switches. In the Remote position, the AFCCU is powered on and

off by the controlling computer system.

Printer

Local/Remote

Switch

Establishes where printer power is controlled. When this switch is in

the Local position, the printer is powered on and off by the Printer

Power On

and the Printer Power Off if in Local switches. In the

Remote position, the printer is powered on and off by the Control Unit

Power On

and Control Unit Power Off If In Local switches on this

panel.

Control Unit

Power On

Switch

Powers on the AFCCU frame or the PUM frame when the Control Unit

Local/Remote

switch is set to Local.

Printer Power

On Switch

Powers on the printer when the Printer Local/Remote switch is set to

Local.

Control Unit

Power Off If In

Local Switch

Powers off the AFCCU when the Control Unit Local/Remote switch is

set to Local.

Printer Power

Off If In Local

Switch

Powers off the printer when the Printer Local/Remote switch is set to

Local.

Emergency

Power Off

Switch

On Printer 1

- When set to Power Enable, the PUM and printer engine

can be powered on by Local or Remote control. Power Off does an

emergency shutdown.

On simplex printers and Printer 2 of a duplex configuration

- When

set to Power Enable, the AFCCU and printer engine can be powered on

by Local or Remote control. Power Off does an emergency shutdown.

All power is removed from the system.

Attention!

Using the Unit Emergency Power Off switch can cause loss of

data and hardware problems; therefore, you should use it only in

an emergency

.

Chapter 3. Functional Areas

19