Table 16. Printer Configuration Items (continued)

Configuration Item

Description

Value Options

Fuser Inactivity

Timer

This entry sets the time, in hours, of printer inactivity

before the fuser is turned off. This saves electrical power

costs and extends the life of the printer. The fuser

automatically turns on when printing resumes, with a

delay until the fuser has reached operating temperature.

A value of 0 means that the timer is not used.

0 to 9 hours. Default is 1 hour.

Eject to Front Facing This entry allows accepting or rejecting the Eject to Front

Facing (EFF) signals sent by the host. A No value will

suppress EFFs. If Yes, the EFF signal from the host will

cause a blank page to be inserted between print jobs if

the prior job contained an odd number of pages.

This option should be set to No if either a postprocessing

device is installed that bursts and stacks output pages, or

if Direct Attach is set to Yes.

Yes or No

Form Definition

Order

When selected, the form definitions are listed in the order

that they were entered.

Yes or No

Stacker Enabled

This entry allows setting of whether or not the stacker is

to be used. A setting of Yes implies that a postprocessing

device is not being used and that fanfold forms (not

roll-feed forms) are being used.

However, if a postprocessing device is installed and

enabled, a Yes value is ignored.

In duplex mode, it refers only to the Printer 2 stacker. In

dual simplex mode, it may refer to either Printer 1 or

Printer 2.

Yes or No

Chapter 8. Configuring the System