Parallel Channel Configuration Information

Table 17 lists all configuration items, the purpose of each item, and the allowable

value options for each item. The factory-set default values are underlined.

Table 17. Parallel Channel Attachment Items

Configuration Item

Description

Value Options

Parallel Link A

Installed

Specifies if Parallel Channel Link A is installed.

Yes or No

Parallel Link B

Installed

Specifies if Parallel Channel Link B is installed.

Yes or No

Device Address

Specifies the 2-digit hexadecimal channel address which

includes the device address.
Notes:

1.

In simplex mode, only one device address is required.
In dual simplex mode, each printer requires a unique

device address. Printer 1 requires an even number

(for example, X'30'); Printer 2 requires the next

consecutive number (for example, X'31').

2.

The duplex system does not require a unique number.

It can use either of the addresses used for dual

simplex Printer 1 or dual simplex Printer 2. However,

it is often easier from an operational viewpoint to

assign duplex a separate address (so the duplex and

simplex printers look like unique devices to the

operating system). The general convention in this case

is to assign the duplex system the next consecutive

address (even) after the address for simplex Printer 2.
For example, if you define Printer 1 in dual simplex

as X'30', you should then define Printer 2 in dual

simplex as X'31', and, optionally, define the complete

system in duplex as X'32'.

3.

The device addresses specified above must match the

device addresses defined to the host PSF software,

and in the case of S/390 hosts, the I/O device

definitions.

00 to FF (Hexadecimal notation).

Default is X'00'

Second Channel

Specifies the switching mode of the Two-Channel Switch:

Static or Dynamic Mode. When a second Parallel Channel

is installed, a Two-Channel Switch facility is provided.
v

Static:

You can enable only one channel at a time. You

can connect two interfaces to two channels on the same

processing unit, on tightly coupled processing units

(units controlled by the same operating system), or on

independent (uncoupled) processing units.

v

Dynamic:

You can enable both channels at the same

time with the two-Channel Switch used as a dynamic

interface switch. Connect the two interfaces to two

channels either on the same processing unit or on

tightly-coupled processing units (units controlled by

the same operating system).

You cannot select this item unless two channels are

installed.

Static or Dynamic

232