beautypg.com

IBM INFO PRINT 3000 User Manual

Page 227

background image

7.

Locate the Developer Mix Inlet (1), the Developer Drain Lever B (2), and the

Developer Run Pushbutton A (3) in the developer area.

Important

a.

Never open the developer drain unless the developer drain hose is

inserted into an empty developer mix bottle.

b.

After you have opened and closed the developer drain, you must

replace the developer mix. Opening the drain resets the developer

mix usage timer. Resetting the timer without changing the developer

mix could result in severe print quality problems that are caused by

the developer mix being used beyond its normal life.

Chapter 7. Ordering and Replacing Supplies

195