beautypg.com

Jam recovery procedures, Jam recovery procedures - simplex mode – IBM INFO PRINT 3000 User Manual

Page 155

background image

Important

To clear the jam message from the Display Touch Screen window, do the

following:
v

For STACKER JAM 161 and STACKER JAM 164, you must open and close the

stacker gate, or you must lower and raise the stacker table.

v

For the jam messages in the following list, SELECT the Check Reset

pushbutton on the Display Touch Screen.

UPPER TRACTOR FORMS JAM 0119
TENSION ARM DOWN 0131
TENSION ARM UP 0132
SKEW ERROR 0133
FUSER WRAP 0134

Jam Recovery Procedures

Table 12. Jam Recovery Procedures - Simplex Mode

Error Message SRC Code (In Numeric

Order)

Recovery Actions

UPPER TRACTOR FORMS JAM 0119
TENSION ARM DOWN 0131
TENSION ARM UP 0132
SKEW ERROR 0133
FUSER WRAP 0134

(Forms are jammed, torn, or separated.)

1.

Clear the forms path. See “Clearing the Forms Path” on page 136.

2.

If any of the Printer Error messages still appear, SELECT the Check

Reset

pushbutton on the Printer Error Display Touch Screen window.

3.

Check for and resolve or postpone any other error or intervention

message appearing on the Display Touch Screen windows.

4.

Reload the forms. See “Loading Forms (Simplex or Dual Simplex

Mode)” on page 102.

5.

SELECT

the Ready pushbutton on the Display Touch Screen window

for the affected printer.

6.

If reprinting is allowed, all unfused pages between the transfer

station and the top of the stacker plus any jam recovery point

distance defined in the printer configuration are reprinted. Check for

and discard duplicate pages.
If the jam was the result of a FUSER WRAP 0134, all lost or damaged

pages may not be reprinted. Work with the host system console

operator to recover these pages.

7.

If reprinting is not allowed, work with the host system console

operator to recover the lost pages.

8.

See “Suggestions for Preventing Jams” on page 144 if the error recurs

frequently.

Chapter 6. Operator Responsibilities

123