MITSUBISHI ELECTRIC FR-S520E User Manual
Fr-s, Transistorized inverter, Instruction manual (detailed)
Table of contents
Document Outline
- FR-S500E INSTRUCTION MANUAL (Detailed)
- This section is specifically about safety matters
- CONTENTS
- 1. WIRING
- 1.1 Standard connection diagram and terminal specifications
- 1.2 Main circuit terminals
- 1.2.1 Terminal block layout
- 1.2.2 Cables, wiring length, and crimping terminals
- 1.2.3 Wiring instructions
- 1.2.4 Selection of peripheral devices
- 1.2.5 Leakage current and installation of earth (ground) leakage circuit breaker
- 1.2.6 Power-off and magnetic contactor (MC)
- 1.2.7 Regarding the installation of the power factor improving reactor
- 1.2.8 Regarding noise and the installation of a noise filter
- 1.2.9 Earthing (Grounding) precautions
- 1.2.10 Power supply harmonics
- 1.2.11 Harmonic suppression guideline
- 1.2.12 Inverter-driven 400V class motor
- 1.3 How to use the control circuit terminals
- 1.4 Input terminals
- 1.4.1 Run (start) and stop (STF, STR, STOP)
- 1.4.2 Connection of frequency setting potentiometer and output frequency meter (10, 2, 5, 4, AU)
- 1.4.3 External frequency selection (REX, RH, RM, RL)
- 1.4.4 Indicator connection and adjustment (FM)
- 1.4.5 Control circuit common terminals (SD, 5, SE)
- 1.4.6 Signal inputs by contactless switches
- 1.5 How to use the input signals (assigned terminals RL, RM, RH, STR)
- 1.5.1 Multi-speed setting (RL, RM, RH, REX signals): Pr. 60 to Pr. 63 setting "0, 1, 2, 8" Remote setting (RL, RM, RH signals): Pr. 60 to Pr. 63 setting "0, 1, 2"
- 1.5.2 Second function selection (RT signal): Pr. 60 to Pr. 63 setting "3"
- 1.5.3 Current input selection "AU signal": Pr. 60 to Pr. 63 setting "4"
- 1.5.4 Start self-holding selection (STOP signal): Pr. 60 to Pr. 63 setting "5"
- 1.5.5 Output shut-off (MRS signal): Pr. 60 to Pr. 63 setting "6"
- 1.5.6 External thermal relay input: Pr. 60 to Pr. 63 setting "7"
- 1.5.7 Jog operation (JOG signal): Pr. 60 to Pr. 63 setting "9"
- 1.5.8 Reset signal: Pr. 60 to Pr. 63 setting "10"
- 1.5.9 PID control valid terminal: Pr. 60 to Pr. 63 setting "14"
- 1.5.10 PU operation/external operation switchover: Pr. 60 to Pr. 63 setting "16"
- 1.6 Connection to the Stand-Alone Option
- 1.7 Handling of the RS-485 connector
- 1.8 Design information
- 2. FUNCTIONS
- 2.1 Function (Parameter) list
- 2.2 List of parameters classified by purpose of use
- 2.3 Explanation of functions (parameters)
- 2.3.1 Torque boost (Pr. 0 , Pr. 46 )
- 2.3.2 Maximum and minimum frequency (Pr. 1 , Pr. 2 )
- 2.3.3 Base frequency, base frequency voltage (Pr.3 , Pr.19 , Pr.47 )
- 2.3.4 Multi-speed operation (Pr. 4, Pr. 5, Pr. 6, Pr. 24 to Pr. 27, Pr. 80 to Pr. 87)
- 2.3.5 Acceleration/deceleration time (Pr. 7 , Pr. 8 , Pr. 20 , Pr. 44 , Pr. 45 )
- 2.3.6 Selection and protection of a motor (Pr. 9 , Pr. 71 , H7 )
- 2.3.7 DC injection brake (Pr. 10 , Pr. 11 , Pr. 12 )
- 2.3.8 Starting frequency (Pr. 13 )
- 2.3.9 Load pattern selection (Pr. 14 )
- 2.3.10 Jog operation (Pr.15 , Pr.16 )
- 2.3.11 RUN key rotation direction selection (Pr.17 )
- 2.3.12 Stall prevention function and current limit function (Pr. 21 )
- 2.3.13 Stall prevention (Pr. 22 , Pr. 23 , Pr. 28 )
- 2.3.14 Acceleration/deceleration pattern (Pr. 29 )
- 2.3.15 Extended function display selection (Pr. 30 )
- 2.3.16 Frequency jump (Pr. 31 to Pr. 36 )
- 2.3.17 Speed display (Pr. 37 )
- 2.3.18 Biases and gains of the frequency setting voltage (current) (Pr. 38 , Pr. 39 , C2 to C7 )
- 2.3.19 Start-time earth (ground) fault detection selection (Pr. 40 )
- 2.4 Output terminal function parameters
- 2.5 Current detection function parameters
- 2.6 Display function parameters
- 2.7 Restart operation parameters
- 2.8 Additional function parameters
- 2.9 Terminal function selection parameters
- 2.10 Operation selection function parameters
- 2.10.1 Retry function (Pr. 66 , Pr. 67 , Pr. 68 , Pr. 69 )
- 2.10.2 PWM carrier frequency and long wiring mode (Pr. 70 , Pr. 72 )
- 2.10.3 Voltage input selection (Pr. 73 )
- 2.10.4 Input filter time constant (Pr. 74 )
- 2.10.5 Reset selection/PU stop selection (Pr. 75 )
- 2.10.6 Cooling fan operation selection (Pr. 76 )
- 2.10.7 Parameter write disable selection (Pr. 77 )
- 2.10.8 Reverse rotation prevention selection (Pr. 78 )
- 2.10.9 Operation mode selection (Pr. 79 )
- 2.10.10 PID control (Pr. 88 to Pr. 94 )
- 2.11 Auxiliary parameters
- 2.12 Maintenance parameters
- 2.13 Brake parameters (FR-S520E-0.4K to 3.7K only)
- 2.14 Calibration parameters
- 2.15 Clear parameters
- 2.16 Communication parameters
- 2.17 Parameter unit (FR-PU04) setting
- 3. PROTECTIVE FUNCTIONS
- 3.1 Errors (Alarms)
- 3.2 Troubleshooting
- 3.2.1 Motor remains stopped
- 3.2.2 Motor rotates in opposite direction
- 3.2.3 Speed greatly differs from the setting
- 3.2.4 Acceleration/deceleration is not smooth
- 3.2.5 Motor current is large
- 3.2.6 Speed does not increase
- 3.2.7 Speed varies during operation
- 3.2.8 Operation mode is not changed properly
- 3.2.9 Operation panel display is not operating
- 3.2.10 Parameter write cannot be performed
- 3.2.11 Motor produces annoying sound
- 4. SPECIFICATIONS
- APPENDIX
- REVISIONS