beautypg.com

7) program example – MITSUBISHI ELECTRIC FR-S520E User Manual

Page 161

background image

151

Communication parameters

2

F

UNCT

IO

NS

(7) Program example

Program

General flowchart

To change the operation mode to computer link operation

1000 *REC
1010 IF LOC(1)=0 THEN RETURN
1020 PRINT"RECEIVE DATA"

1040 RETURN

140 GOTO 50

Interrupt data receive

1030 PRINT INPUT$(LOC(1),#1)

130 PRINT#1,D$

Data send

Initial setting of I/O file

Line number

Interrupt occurrence during data receive

30 ON COM(1)GOSUB*REC

20 COMST1,1,1:COMST1,2,1

10 OPEN"COM1:9600,E,8,2,HD"AS #1

Opening the communication file

40 COM(1)ON

50 D$="01FB10000"

Send data setting

Sum code calculation

80 A$=MID$(D$,I,1)

90 A=ASC(A$)

100 S=S+A

110 NEXT I

70 FOR I=1 TO LEN(D$)

60 S=0

Addition of control and sum codes

120 D$=CHR$(&H5)+D$+RIGHT$(HEX$(S),2)

ON/OFF setting of circuit control signals (RS, ER)

Interrupt enable

Interrupt definition for data receive

to

to

Line number

I/O file initial

setting

50

140

to

10

40

1000

1040

Interrupt

Receive data processing
Data import
Screen display

Send data processing
Data setting
Sum code calculation
Data send

This manual is related to the following products: