beautypg.com

MITSUBISHI ELECTRIC FR-S520E User Manual

Page 156

background image

146

Communication parameters

After completion of parameter settings, set the instruction codes and data then start
communication from the computer to allow various types of operation control and
monitoring.

No.

Item

Instruction

Code

Description

Number

of Data

Digits

1

Operation
mode

Read

H7B

H0000: Communication operation
H0001: External operation
H0002: PU operation

4 digits

Write

HFB

H0000: Communication operation
H0001: External operation

2

M

oni

to

ri

ng

Output
frequency
[speed]

H6F

H0000 to HFFFF: Output frequency in 0.01Hz
increments
Pr. 37 = 0 (factory setting)

4 digits

H0000 to HFFFF: Speed in 1r/min increments
When Pr. 37 = "0.1 to 999", expansion link parameter (HFF)
= 0
H000000 to HFFFFFF: Speed in 0.01r/min increments
When Pr. 37 = "0.1 to 999", expansion link parameter (HFF)
= 1

6 digits

Output
current

H70

H0000 to HFFFF: Output current (hexadecimal) in 0.01A
increments

4 digits

Alarm
definition

H74 to H75

H0000 to HFFFF: Two most recent alarm definitions
Alarm definition display example (instruction code H74)

* Error code may not be returned.

4 digits

b15

b8b7

b0

0 0 1 1 0 0

0

0

0 0 0 0 0

0

1

1

Previous alarm

(H30)

Most recent alarm

(HA0)

Alarm data

Data

Description Data

Description

H00

No alarm

H60

OLT

H10

OC1

H70

BE

H11

OC2

H80

GF

H12

OC3

H90

OHT

H20

OV1

HA0

OPT

H21

OV2

HB0

PE

H22

OV3

HB1

PUE

H30

THT

HB2

RET

H31

THM

HC0

CPU*

H40

FIN

This manual is related to the following products: