MITSUBISHI ELECTRIC FR-S520E User Manual
Page 113
103
Terminal function selection parameters
2
F
UNCT
IO
NS
Refer to the following table and set the parameters:
*1.When Pr. 59 = "1 or 2", the functions of the RL, RM and RH signals change as
listed above.
*2.Actuated when the relay contact "opens".
*3.When using the REX signal, an external command cannot be used to make a
reverse rotation start.
Setting
Signal
Name
Functions
Related Parameters
0
RL
Pr. 59 = "0"
Low-speed operation
command
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 80 to Pr. 87
Pr. 59 = "1", "2" (*1)
Remote setting
(setting clear)
Pr. 59
1
RM
Pr. 59 = "0"
Middle-speed
operation command
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 80 to Pr. 87
Pr. 59 = "1", "2" (*1)
Remote setting
(deceleration)
Pr. 59
2
RH
Pr. 59 = "0"
High-speed operation
command
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 80 to Pr. 87
Pr. 59 = "1", "2" (*1)
Remote setting
(acceleration)
Pr. 59
3
RT
Second function selection
Pr. 44 to Pr. 47, H7
4
AU
Current input selection
5
STOP
Start self-holding selection
6
MRS
Output shut-off stop
7
OH
External thermal relay input (*2)
The inverter stops when the externally
provided thermal relay for overheat
protection, motor's embedded temperature
relay etc. is actuated.
Refer to page 164.
8
REX
15-speed selection (combination with 3
speeds RL, RM, RH) (*3)
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 80 to Pr. 87
9
JOG
Jog operation selection
Pr. 15, Pr. 16
10
RES
Reset
Pr. 75
14
X14
PID control presence/absence selection
Pr. 88 to Pr. 94
16
X16
PU-external operation switch-over
Pr. 79 (setting: 8)
- - -
STR
Reverse rotation start
(can be assigned to STR
terminal (Pr. 63) only)
REMARKS
•One function can be assigned to two or more terminals. In this case, the function is activated
when one of the multiple terminals used for assignment turns on.
•The speed command priorities are higher in order of jog, multi-speed setting (RH, RM, RL,
REX) and AU.
•Use common terminals to assign multi-speeds (7 speeds) and remote setting. They cannot
be set individually.
(Common terminals are used since these functions are designed for speed setting and need
not be set at the same time.)