beautypg.com

Caution – MITSUBISHI ELECTRIC FR-S520E User Manual

Page 84

background image

74

Explanation of functions (parameters)

REMARKS

•When running two motors with one inverter, you can set the electronic thermal relay function

of each inverter.

CAUTION

Set this parameter correctly according to the motor used.
Incorrect setting may cause the motor to overheat and burn.

Pr. 71

applied

motor

First Motor Electronic Thermal Relay

Function

Second Motor Electronic Thermal

Relay Function

Pr. 9

setting

RT = OFF

RT = ON

additional

parameter
H7 setting

RT = OFF

RT = ON

0

0

- - -, 0

0.1 to 50A

standard

0.1 to 50A

standard

- - -

0

0.1 to 50A

standard

1

0

- - -, 0

0.1 to 50A

standard

0.1 to 50A

constant-

torque

- - -

0

0.1 to 50A

standard

100

0

- - -, 0

0.1 to 50A

constant-
torque

0.1 to 50A

standard

- - -

0

0.1 to 50A

constant-
torque

101

0

- - -, 0

0.1 to 50A

constant-
torque

0.1 to 50A

constant-

torque

- - -

0

0.1 to 50A

constant-
torque

standard ...................Thermal characteristic for

standard motor

constant-torque ........Thermal characteristic for

constant-torque motor

..... Output current value is used to

perform integration processing.

..... Perform integration processing

using output current of 0A.

..... Electronic thermal relay function

is not activated (cumulative
value clear)

This manual is related to the following products: