beautypg.com

MITSUBISHI ELECTRIC FR-S520E User Manual

Page 45

background image

35

Input terminals

1

WI

RING

Output waveform of terminal FM

The output signal of terminal FM has a pulse waveform as shown in the table below
and the number of its pulses is proportional to the inverter output frequency.
The output voltage (average voltage) is also proportional to the output frequency.

Terminal FM Output Voltage

*1. 0.5V or less when a DC ammeter of 300

Ω or less internal resistance is connected to

measure the output voltage.

Analog meter

To adjust the reading of an analog indicator (ammeter), turn the calibration resistor to
change the current.
When using the operation panel or parameter unit for adjustment, change the pulse
width of the output waveform (calibration parameter "C1") (adjust the current through
the adjustment of the output voltage) to adjust the reading. (For details, refer to page
131.)

Specifications

Example of Inverter and Frequency

Meter

Output

waveform

Number of

output

pulses

(pulses/

second)

Max. 2400 pulses/s

Set a full-scale value which

achieves 1440 pulses/s.

Pr. 55: frequency monitoring

reference

Pr. 56: current monitoring

reference

Output

voltage

0 to 8VDC max. (*1)

(Approx. 5V at 1440 pulses/s)

Adjustment

REMARKS

It is not recommended to use a voltage type indicator because it is easily affected by a voltage
drop, induction noise, etc. and may not provide correct reading if the wiring distance is long.

Inverter

24V

SD

FM

FM

Calibration parameter C1 (Pr. 900)

8V

This manual is related to the following products: