beautypg.com

MITSUBISHI ELECTRIC FR-S520E User Manual

Page 81

background image

71

Explanation of functions (parameters)

2

F

UNCT

IO

NS

2.3.5

Acceleration/deceleration time (Pr. 7

, Pr. 8

,

Pr. 20

, Pr. 44

, Pr. 45

)

CAUTION

1. The multi-speed settings override the main speeds (across terminals 2-5, 4-

5, setting dial). When the multi-speed settings and setting dial are used in
the combined operation mode (Pr. 79=3), the multi-speed settings have
precedence.

2. The multi-speeds can also be set in the PU or external operation mode.
3. For 3-speed setting, if two or three speeds are simultaneously selected,

priority is given to the set frequency of the lower signal.

4. Pr. 24 to Pr. 27 and Pr. 80 to Pr. 87 settings have no priority between them.
5. The parameter values can be changed during operation.
6. When using this function with the jog signal, the jog signal has precedence.

REMARKS

The frequency-set external terminals have the following priority:
Jog > multi-speed operation > AU (terminal 4) > terminal 2

Related parameters

Maximum, minimum frequency setting

Pr. 1 "maximum frequency", Pr. 2 "minimum frequency"

(refer to page 68)

Assignment of signals RH, RM, RL, REX to terminals

Pr. 60 to Pr. 63 (input terminal function

selection) (refer to page 102)

External operation mode setting

Pr. 79 "operation mode selection" (refer to page 113)

Computer link mode

Pr. 79 "operation mode selection" (refer to page 113), communication

parameter n10 "link startup mode selection" (refer to page 153)

Speed command source

Communication parameter n9 "speed command source"

(refer to page 152)

Used to set motor acceleration/
deceleration time.
Set a larger value for a slower
speed increase/decrease or a
smaller value for a faster speed
increase/decrease.

Parameter

Name

Factory

Setting

Setting

Range

Remarks

7

Acceleration time

5s

0 to 999s

----------

8

Deceleration time

5s

0 to 999s

----------

20

Acceleration/
deceleration reference
frequency

60Hz

1 to 120Hz

Setting is enabled when
Pr. 30 = "1".

44

Second acceleration/
deceleration time

5s

0 to 999s

Setting is enabled when
Pr. 30 = "1".

45

Second deceleration
time

- - -

0 to 999s,

- - -

- - -:
acceleration time=
deceleration time.

Setting is
enabled when
Pr. 30 = "1".

Running
frequency

Acceleration

time

Deceleration

time

Time

Pr.20

Out

put

f

re

quen

cy

(Hz)

Pr.7
Pr.44

Pr.8
Pr.45

Acceleration

Deceleration

Constant speed

This manual is related to the following products: