Display function parameters
2.6 Display function parameters
2.6.1
Monitor display (Pr. 52
, Pr. 54
)
When "100" is set in Pr. 52, the monitored values during stop and during operation
differ as indicated below.
You can choose the display of the operation panel "monitor/frequency setting
screen".
Parameter
Name
Factory
Setting
Setting
Range
Remarks
52
Operation panel
display data
selection
0
0, 1, 100
Setting is enabled when Pr. 30 = "1"
54
FM terminal function
selection
0
0, 1
POINT
•You can also use the
to change the display. (Refer to the instruction manual
(basic) for the operation procedure.)
•The pulse train output terminal FM is available for signal output. (Make selection
using the Pr. 54 "FM terminal function selection" value.)
Signal Type
Unit
Parameter Setting
Full-Scale Value of FM
Level Meter
Pr. 52
Pr. 54
Operation panel
LED
FM terminal
Output frequency
Hz
0/100
0
Pr. 55 "frequency monitoring
reference"
Output current
A
1
1
Pr. 56 "current monitoring
reference"
Pr. 52
0
100
During running/stop
During stop
During running
Output frequency
Output frequency
Set frequency
Output frequency
REMARKS
•During an error, its definition appears.
•During reset, the values displayed are the same as during a stop.
•For selection of the parameter unit (FR-PU04) monitor display, refer to the communication
parameter n16 "PU main display screen data selection". (Page 157)
CAUTION
The unit displayed on the operation panel is only A and other units are not
displayed.
♦Related parameters♦
• Speed display
⇒
Pr. 37 "speed display" (refer to page 85)
• Adjustment of FM level meter full-scale value
⇒
Calibration parameter C1 "FM terminal calibration"
(refer to page 131)
• Monitoring reference
⇒
Pr. 55 "frequency monitoring reference", Pr. 56 "current monitoring
reference" (refer to page 96)
SET