MITSUBISHI ELECTRIC FR-S520E User Manual

Page 67

background image

57

Function (Parameter) list

2

F

UNCT

IO

NS

P

a

ra

me

te

r L

ist

T

e

rm

in

al

f

u

nc

ti

on

s

e

le

c

ti

o

n

60

RL terminal
function
selection

0: RL, 1: RM, 2: RH,
3: RT, 4: AU, 5: STOP,
6: MRS, 7: OH,
8: REX, 9: JOG,
10: RES, 14: X14,
16: X16,
- - -: STR (The STR
signal can be
assigned to the STR
terminal only.)

1

0

102

61

RM terminal
function
selection

1

1

102

62

RH terminal
function
selection

1

2

102

63

STR terminal
function
selection

1

- - -

102

64

RUN terminal
function
selection

0:RUN, 1:SU, 3:OL,
4:FU, 11:RY, 12:Y12,
13:Y13, 14:FDN,
15:FUP, 16:RL,
93:Y93, 95:Y95 98:LF,
99:ABC
(The Y93 signal can
be assigned to the
RUN terminal only.)

1

0

104

65

A, B, C
terminal
function
selection

1

99

104

O

per

at

ion se

le

ct

ion f

u

n

c

ti

o

n

s

66

Retry
selection

0: OC1 to 3, OV1 to 3,

THM, THT, BE, GF,
OHT, OLT, PE, OPT

1: OC1 to 3,
2: OV1 to 3,
3: OC1 to 3, OV1 to 3

1

0

105

67

Number of
retries at
alarm
occurrence

0: No retry
1 to 10:
Without alarm output
during retry operation
101 to 110:
With alarm output
during retry operation

1

0

105

68

Retry waiting
time

0.1 to 360s

0.1s

1s

105

69

Retry count
display erase

0: Cumulative count

erase

1

0

105

Func-

tion

Para-

meter

Indica-

tion

Name

Setting Range

Minimum

Setting

Increments

Factory

Setting

Refer

To:

Cus-

tomer

Setting