beautypg.com

2 cables, wiring length, and crimping terminals – MITSUBISHI ELECTRIC FR-S520E User Manual

Page 18

background image

8

Main circuit terminals

1.2.2

Cables, wiring length, and crimping terminals

The following table indicates a selection example for the wiring length of 20m.
1) Three-phase 200V power input

2) Three-phase 400V power input

3) Single-phase 200V power input

4) Single-phase 100V power input

Wiring length
100m maximum. (50m maximum for the FR-S540E-0.4K.)

Applied Inverter

Ter-

minal

Screw

size

Tight-

ening

Torque

N

m

Crimping

Terminal

Cable

PVC Insulation

Cable

mm

2

AWG

mm

2

R, S, T U, V, W R, S, T U, V, W R, S, T U, V, W R, S, T U, V, W

FR-S520E-0.1K
to 0.75K (-C)

M3.5

1.2

2-3.5

2-3.5

2

2

14

14

2.5

2.5

FR-S520E-
1.5K, 2.2K (-C)

M4

1.5

2-4

2-4

2

2

14

14

2.5

2.5

FR-S520E-3.7K
(-C)

M4

1.5

5.5-4

5.5-4

3.5

3.5

12

12

4

2.5

Applied Inverter

Ter-

minal

Screw

size

Tight-

ening

Torque

N

m

Crimping

Terminal

Cable

PVC Insulation

Cable

mm

2

AWG

mm

2

R, S, T U, V, W R, S, T U, V, W R, S, T U, V, W R, S, T U, V, W

FR-S540E-0.4K
to 3.7K

M4

1.5

2-4

2-4

2

2

14

14

2.5

2.5

Applied Inverter

Termi-

nal

Screw

size

Tight-

ening

Torque

N

m

Crimping

Terminal

Cable

PVC Insulation

Cable

mm

2

AWG

mm

2

U, V, W

U, V, W

U, V, W

U, V, W

FR-S520SE-0.1K
to 0.75K

M3.5

1.2

2-3.5

2-3.5

2

2

14

14

2.5

2.5

FR-S520SE-1.5K

M4

1.5

2-4

2-4

2

2

14

14

2.5

2.5

Applied Inverter

Termi-

nal

Screw

size

Tight-

ening

Torque

N

m

Crimping

Terminal

Cable

PVC Insulation

Cable

mm

2

AWG

mm

2

R, S U, V, W R, S U, V, W R, S U, V, W

R, S

U, V, W

FR-S510WE-0.1K
to 0.4K

M3.5

1.2

2-3.5

2-3.5

2

2

14

14

2.5

2.5

FR-S510WE-0.75K

M4

1.5

5.5-4

2-4

3.5

2

12

14

4

2.5

CAUTION

When the wiring length of the 0.1K and 0.2K of the three-phase 200V, single-

phase 200V, and single-phase 100V class and 0.4K and 0.75K of the three-
phase 400V class is 30m or more, set the carrier frequency to 1kHz.

When automatic torque boost is selected in Pr. 98 "automatic torque boost

selection (motor capacity)", the wiring length should be 30m maximum. (Refer
to page 125.)

This manual is related to the following products: