beautypg.com

MITSUBISHI ELECTRIC FR-S520E User Manual

Page 187

background image

177

Specification list

4

SPECI

F

ICATI

O

N

S

(4) Single-phase 100V power supply

*1. The applied motor capacity indicated is the maximum capacity applicable when a

Mitsubishi 4-pole standard motor is used.

*2. The rated output capacity indicated assumes that the output voltage is 230V.
*3. The % value of the overload current rating indicates the ratio of the overload current to the

inverter's rated output current.
For repeated duty, allow time for the inverter to return to or below the temperatures under
100% load.

*4. For single-phase 100V power input, the output voltage provided cannot be twice or more

than the power supply voltage.

*5. The power supply capacity changes with the values of the power supply side inverter

impedances (including those of the input reactor and cables).

*6. For single-phase 100V power input, the application of motor load reduces the output

voltage about 10 to 15%. Therefore, the load must be reduced when a general-purpose
motor is used.

Type FR-S510WE-

K

0.1

0.2

0.4

0.75

Applied motor capacity (kW) (*1)

0.1

0.2

0.4

0.75

Ou

tp

u

t

Rated capacity (kVA) (*2)

0.3

0.5

1.0

1.6

Rated current (A)

0.8

1.4

2.5

4.1

Overload current rating (*3)

150% 60s, 200% 0.5s (Inverse time characteristics)

Voltage

Three phase, 200V to 230V 50Hz/60Hz (*4, 6)

Po

we

r s

u

p

p

ly Rated input AC voltage/frequency

Single-phase, 100V to 115V 50Hz/60Hz

Permissible AC voltage fluctuation

90 to 132V 50Hz/60Hz

Permissible frequency fluctuation

±5%

Power supply system capacity
(kVA) (*5)

0.5

0.9

1.5

2.5

Protective structure (JEM1030)

Enclosed type (IP20)

Cooling system

Self-cooling

Approximate mass (kg)

0.6

0.7

0.9

1.6

This manual is related to the following products: