MITSUBISHI ELECTRIC FR-S520E User Manual
Page 17
7
Main circuit terminals
1
WI
RING
3) Single-phase 200V power input
• FR-S520SE-0.1K, 0.2K, 0.4K, 0.75K
• FR-S520SE-1.5K
4) Single-phase 100V power input
• FR-S510WE-0.1K, 0.2K, 0.4K
• FR-S510WE-0.75K
CAUTION
•Make sure the power cables are connected to the R/L1, S/L2, T/L3 of the inverter.
Never connect the power cable to the U, V, W of the inverter. (Phase need not be
matched)
•Connect the motor to U, V, W. At this time, turning on the forward rotation switch
(signal) rotates the motor in the counterclockwise direction when viewed from the
motor shaft.
P1
Motor
Jumper
U
V W
IM
Power supply
R/L1 S/L2
P/+
N/-
P1
Jumper
Motor
U V W
IM
Power supply
P/+
N/-
R/L1 S/L2
Motor
U V W
IM
Power supply
R/L1 S/L2
P/+
N/-
Motor
U V W
IM
Power supply
P/+
N/-
R/L1 S/L2